Modify the structure of a building pad by assigning a function to each layer in the assembly.
- Open the site plan that contains the building pad.
- Select the building pad.
Note: Use
Tab to cycle through the selection options. Selection options are displayed on the left side of the status bar.
- Click Modify | Pads tabProperties panel (Type Properties).
- In the Type Properties dialog, for Structure, click Edit.
- In the Edit Assembly dialog, set the function for each layer.
Each layer must have a function assigned to it, so
Revit can match layers accurately. Layers can be assigned for the following functions:
- Structure. A layer that supports the remainder of the building pad.
- Substrate. A material that acts as a foundation for another material.
- Thermal/Air Layer. A layer that provides insulation and prevents air penetration
- Finish 1. A finish layer, for example, the top surface of the building pad.
- Finish 2. A finish layer, for example, the bottom surface of the building pad.
- Membrane Layer. A membrane of zero thickness that prevents water vapor penetration.
Note: The Wraps check box can be left unchecked.
- Set the Material and Thickness for each layer.
- Click Insert to add a new layer. Click Up or Down to change the layer order.
- Click OK twice.