FORCED_EXTRA

Summary: Change the default number of thermal-only iterations when running staged forced convection.

Flag

FORCED_EXTRA A

A = thermal only iterations to run with staged forced convection (250 is default).

Description

Staged forced convection automates the two-step process of running forced convection (flow-only convergence followed by thermal-only.) This approach is valid because fluid properties are not temperature-dependent in forced convection heat transfer.

When Staged Forced Convection is enabled, the flow analysis is automatically followed by 250 thermal-only iterations.

Enable this flag, and specify greater than 250 to run additional thermal-only iterations. Note that the analysis stops either when the number of iterations have elapsed or when Intelligent Convergence Assessment detects the thermal solution is converged, whichever comes first.

For more about Automatic Forced Convection