Data Extraction and Results Visualization of Heat Exchangers

A tooltip displays the resultant heat exchanger performance data. To view the tooltip, hover over the heat exchanger part (while the Global result task is active) or over the part in the Results > Material branch of the Design Study bar. The tooltip contains the following information:

Note that this data is also available in the Summary file. (Results tab > Review panel > Summary File.)

The following shows that no results are displayed on the heat exchanger device (A). To view its effect on the system, display temperature near the inlet and outlet:

The air at the heat exchanger inlet (B) is clearly warmer than the outlet air (C). The temperature drop indicates that this heat exchanger has removed heat from the working fluid.