To set Point-Cloud Single Point parameters for the active measure

To specify how measurements are taken and reported for point-cloud single points:

  1. Click Measure tab > Current panel > Parameters.
  2. In the Measure Parameters dialog, select the Point Cloud Single Point tab.
    Note: Point-cloud single point parameters are available only when creating inspections for CNC and Manual machines.
  3. Select the Consider points within catchment zone only check box to ignore points outside the catchment zone. Deselect the check box to consider all scanned points.
  4. In the Catchment zone radius box, enter the maximum distance from the nominal at which points can be recorded. Points exceeding this distance are not recorded.
  5. Select the Auto-accept on scan completion if there are points within check box, and enter a value in the box, to automatically accept a point within the distance entered.
  6. Select Save as default parameters if you want to use these values as the defaults for new inspections.