Use the
Point Cloud Acquisition Options dialog to control how
PowerInspect treats points measured with a laser scanner.
- Play the Point Cloud item.
PowerInspect switches to full-screen view.
- On the
Point-Cloud Tool
dialog, click the
Parameters
button.
- To project acquired points onto the model:
- Select
Project acquired points on the fly.
- Enter a value in the
Proximity criteria box to specify the maximum distance from the nominal at which points are accepted. Points exceeding this distance are not recorded.
- To reduce the number of acquired points:
- Select
Filter the incoming points to reduce density.
- Enter a value in the Filter tolerance box. A point is recorded only when its distance from the preceding point exceeds the tolerance distance.
- By default, the full-screen view automatically adjusts to display all acquired points. To also display all visible items, select
Automatic zooming.
- To reject acquired points below a specified plane:
- Select
Use a clipping plane to limit data acquisition.
- Choose a plane from the list.
- Enter a value in the
Offset box to specify the maximum distance from the plane at which points are accepted. Points exceeding this distance are not recorded.
- To display the excluded points below the plane during scanning, select
Show the rejected points as a selection. The points are displayed in the
Rejected colour that is specified in the
Options dialog. The colour is black by default.
Note: The
Point-Cloud Tool
dialog is available only when creating inspections for CNC and Manual machines.