To extract CAD nominals for a Probed Single Point item

When you have a model, you can extract the nominal position of a Probed Single Point using a dynamic point.

To extract the nominal position of a point:

  1. Select the CAD View tab.
  2. Click Home tab > Mouse Context panel > Dynamic Points Editor. The Dynamic Points context tab is displayed.
  3. Double-click the CAD model to create a dynamic point at the position of the Probed Single Point.
  4. Select the dynamic point. The point changes from green to red.
  5. To copy the coordinates to the clipboard, click Home tab > Edit panel > Copy.
  6. To paste the coordinates into the Probed Single Point item, open the Probed Single Point dialog, then click the Paste button in the Target point area. This button is not displayed if more than one point is selected.