Provides a quick guide to which commands and system variables are changed in this release.
Updated system variable | Description | How changed |
---|---|---|
PLANTCOPYLINENUMBER |
Determines whether to maintain the same line number when copying from an existing pipeline in both P&ID and 3D drawings. |
When an sLine is copied, its line group properties within the tag are also duplicated. Additionally, if the PLANTCOPYLINENUMBER system variable is turned on, the copied sLine is also added into the original line group. |
Updated system variable | Description | How changed |
---|---|---|
PLANTORTHOUPDATE |
Updates the content of an existing view or all views within the same ortho drawing. |
Added a new All command option to update all ortho views within the same drawing. |
Updated system variable | Description | How changed |
---|---|---|
PLANTPCFUNICODE |
Determines whether Unicode PCF files are created. |
Default value has been changed to 1 (ON). |
Updated command | Description | How changed |
---|---|---|
PLANTORTHOPLACEBOM |
Creates an Ortho BOM table. |
New options for creating ortho BOM tables. |
Updated command | Description | How changed |
---|---|---|
PLANTAUDITDATABASE |
Evaluates the integrity of a project and corrects errors in the collaboration project. |
Orphaned records from deleted or missing drawings in collaboration projects can now be audited. |
Updated command | Description | How changed |
---|---|---|
PLANTVAULTRECONCILEPROJECT |
Updates synchronization data in the plant master database (SQL Server). |
Replicated Plant Database option has been removed. |
Updated system variable | Description | How changed |
---|---|---|
PLANTINSULATIONDISPLAY |
Controls whether insulation is displayed on AutoCAD Plant 3D 2025 toolset piping objects. |
The default value has been changed from 1 to 0. |