Common Data Fields

This topic contains information on all the common data fields that can be found for most objects:

These common data fields are described in the table or in the sections below.

User Fields

User fields are used to store any additional information for an object that is not stored in the object's other data fields.

Field Name

Help Text

Database Field

Data Type

Size

Units

Precision

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

User number 1

Used to store any additional number value in the database.

user_number_1

Double

3

User number 2 to User number 10

See User Number 1

user_number_2

to

user_number_10

Double

3

User text 1

Used to store any additional string value in the database.

user_text_1

Text

100

0

User text 2 to User text 10

See User Text 1

user_text_2

to

user_text_10

Text

100

0

Hyperlinks

Field Name

Help Text

Database Field

Data Type

Size

Units

Precision

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

Hyperlinks

Hyperlinks are used to associate external files or internet addresses with objects in the model.

Database Table Name: hyperlink

Position in Data Structure

Field Name

Help Text

Database Field

Data Type

Size

Units

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

1 Description Description of the hyperlinked file description Text 1024

2 URL The path or URL for the file. Browse for a local file using the Browse button url Text 1024

hyperlink

Array

0

Notes

Field Name

Help Text

Database Field

Data Type

Size

Units

Precision

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

Notes

The Notes section is where relevant information for the network object can be found.

notes

Memo

0

Results

When you have a simulation open, you can display a property sheet in the normal way. The sheet will contain fields displaying summary results for the network object. It is very easy to toggle between the results and the corresponding network object views of the Property Sheet by using the Show Results button of the Object Properties Window.

Regulator

This section is only displayed when the type of a control is set to one of those types that can be used in Real Time Control mode.

Those types are:

  • VLDOrf - variable opening orifice
  • VspPmp - variable speed pump
  • VfdPmp - variable frequency drive pump
  • VsGate - variable opening sluice
  • VCWeir - variable crest (height) weir
  • VWWeir - variable width weir

The parameters displayed are as follows:

Minimum valueMaximum value

The limits for the value of the variable parameter.

Important Note: for variable crest weirs the maximum and minimum value is specified in mAD / ftAD and not m / ft. However, the units are always displayed in m / ft due to one set of display units being used for both VcWeir and VwWeir objects. The units for VwWeir objects are correctly displayed.

Positive changeNegative change

The rate of change of the variable parameter once the threshold is exceeded

Threshold

The minimum change that must occur in the parameter being control (for example flow) before any change occurs in the control