Building results are displayed in the Object Properties Window while viewing a replay of a simulation.
Time varying results are shown with the field name in an alternate colour on the grid. Non-time varying results have the field name in the normal black type.
Database Table Name: _IWR_BUILDING
Field Name |
Description |
Database Field |
|
---|---|---|---|
Effective rainfall |
This is the total depth of rainfall on impervious surfaces, minus evaporation. |
Y |
EFFRAIN |
Rainfall profile |
The rainfall profile applied to the building during the simulation. During most simulations this will be the profile entered in the Rainfall profile field. When using a Rainfall Event containing rain-gauge boundary data, this profile depends on which rain-gauge boundary contains the drainage node. |
|
RAINPROF |
Evaporation profile | The evaporation profile applied to the building during the simulation. This is the profile that is specified on the Evaporation profile field in the building's properties. | EVAPPROF | |
Exceedance volume |
Applicable to a building that has its Limit drain to capacity box checked. The total volume, in excess of the Capacity limit, from the building that is either lost or directed either to the 2D element where its Drains to node is located or to its perimeter. |
VO | V_EXCEEDANCE |
Runoff |
The maximum flow from the building roof. |
Q |
RUNOFF |
Total outflow |
The maximum total outflow (runoff and SUDS control net outflow) from the building |
Q |
QCATCH |
Exceedance flow |
Applicable to a building that has its Limit drain to capacity box checked. The maximum flow, in excess of the Capacity limit, from the building that is either lost or directed either to the 2D element where its Drains to node is located or to its perimeter. |
Q |
Q_EXCEEDANCE |
Max enclosed volume |
The maximum volume within the building experienced during the simulation |
VO |
MAXVOLUME2D |
Max flow into building |
The maximum flow into the building experienced during the simulation |
Q |
MAXFLOW2D |
Max highest depth |
The maximum highest depth value experienced during the simulation. |
Y |
MAXHIGHDEPTH2D |
Max highest elevation |
The maximum highest elevation value experienced during the simulation. A null value will be displayed if elements associated with the building are dry throughout the simulation. |
Z |
MAXHIGHELEVATION2D |
Field Name |
Description |
Database Field |
|
---|---|---|---|
Total outflow |
The total outflow (runoff and SUDS control net outflow) from the building |
Q |
QCATCH |
Exceedance flow |
Applicable to a building that has its Limit drain to capacity box checked. The flow, in excess of the Capacity limit, from the building that is either lost or directed either to the 2D element where its Drains to node is located or to its perimeter. |
Q |
Q_EXCEEDANCE |
Enclosed volume |
The Enclosed volume result is calculated as the sum of water depth x element area of all 2D mesh elements within the building boundary. |
VO |
VOLUME2D |
Flow into building |
For each 2D mesh element that the building polygon intersects:
The flow into the building is calculated by summing the flows across each boundary segment. Flow directed into the building is counted positive and flow directed out of the building is counted negative. |
Q |
FLOW2D |
Highest depth |
The maximum of the depth values, at a given timestep, of all the 2D mesh elements inside building boundary |
Y |
HIGHDEPTH2D |
Highest elevation |
The maximum of the elevation values, at a given timestep, of all the 2D mesh elements inside the building boundary. A null value will be displayed for timesteps at which the elements associated with the building are dry. |
Z |
HIGHELEVATION2D |