In this task, you move the injection location to the bottom edge of the part.
Click then Save > Save Study As.
Enter Panel Bottom Location as the new name and click Save.
Click Select from the Navigation bar.
Right-click on the yellow injection location cone and select Properties.
Set the X value to 245 mm.
Set the Y value to 10.55 mm.
Set the Z value to 12 mm.
Click OK to set the location to the bottom edge of the part.
Click (Home > Analysis > Start Analysis).
When the analysis is finished, click Summary in the lower right corner to close the Summary panel.
You will next compare the differences changing an Injection location can cause.