Create a branch table legend, specify the fittings to use for a branch type, and assign a legend symbol for each type. Use these legend symbols to populate the branch table.
Create a Branch Table Legend
- In the Branch Table tab, on the Legend pane, click Edit.
- In the Branch Table Setup dialog box, under Branch Connection Part Setup, click Add Branch.
- In the new branch row, in the Part Type list, click the desired connection part type or Pipe (stub-in).
- If you want to override part-use priority, in the Spec Part list, click a specific part.
- If you want to use an additional reducing part to connect to the branch pipe, do the following:
- Select Add Reducer.
- In the new reducer row, in the Part Type list, click the reducing part type.
- If you want to override part-use priority for the reducing part, in the Spec Part list, click a specific reducing part.
- In Legend Symbol, double-click and enter the branch symbol.
- Click OK.
Assign Branch Fittings in the Branch Table and Set Their Priority
- In the Branch Table tab, on the branch table, click one or more cells that intersect with the header and branch sizes for which you want to provide a fitting.
- Right-click any selected cell. Click Multi Branch Selection.
- In the Select Branch List dialog box, in the Use Branch column, select the branch fittings you want to use in the piping model.
- Click the Priority arrows to move the fitting up or down the list.
- Click OK.
Select Multiple Cells in the Branch Table
- In the Branch Table tab, on the branch table, click a cell for the starting point.
- Do one of the following:
- To select sequential cells, Shift+click cells in the table. Release the Shift key.
- To select multiple non-sequential cells, Ctrl+click cells in the table. Release the Ctrl key.