Review or modify an injection molding simulation study setup

Note: The Setup Summary opens automatically when you create a new injection molding simulation study.
  1. On the Setup tab, click Solve > Setup Summary setup summary icon.

    The Setup Summary dialog opens.

  2. Click the following icons to modify the settings:

    • Target Body target body icon
    • Material materials icon
    • Injection Locations injection location icon
    • Injection Time, Melt Temperature, or Mold Surface Temperature process settings icon
    • Aesthetic Faces aesthetic faces icon
  3. If the error setup summary icon or warning setup summary icon icon is showing, click the icon to find more instructions on what you should or could improve.

  4. When the study setup is ready, click Solve to open the Solve dialog.

  5. Click Solve Study to start the injection molding simulation analysis.

    The Job Status opens, where you can track the progress.

  6. When the results are ready, click Results in the Action column to view the results.