Release Notes

The following list outlines the maintenance fixes included in InfoWater Pro version 2027.3.

For a list of the latest features and improvements in the current release, refer to What's New.

Criticality Analysis

Distance values use model units
Criticality Analysis now converts distance values to the model's unit system before geospatial processing runs.
Isolation area valve counts include internal valves
The valve count for an isolation area now includes the valves inside that area.
F1 opens help
Press F1 in the Criticality Analysis window to open the related help topic.
Duplicate system valves are flagged
Geospatial analysis now detects system valves at the same location. It shows a warning and excludes the duplicate valves from the analysis.
Missing junction elevations are handled
Criticality Analysis now runs when some junctions have no elevation value. It also reads elevations correctly when the Junction.dbf index is out of date.
Inactive elements are excluded
Criticality Analysis now uses only the active network. Inactive elements aren't included in the analysis.

Maps

Pump and valve symbols no longer need geoprocessing
InfoWater Pro now calculates pump and valve symbol angles internally instead of running an ArcGIS Pro geoprocessing tool.
Map Theme save confirmation stays open
When you select Apply and close with unsaved sub-theme changes, the save confirmation stays open until you respond.
Map no longer zooms to a reversed pipe
After you reverse a pipe, selecting another element no longer zooms the map back to the reversed pipe.
Node Polygon layers are replaced, not stacked
Applying a Map Theme now removes Node Polygon layers that aren't active in that theme. Applying a Node Polygon sub-theme replaces any Node Polygon sub-theme applied before it.

Unidirectional Flushing (UDF)

Printing a field journal no longer fails
Printing a UDF field journal no longer fails while the map zooms to the sequence extent.
Notes stay linked to their sequence
Notes attached to a UDF sequence now stay with that sequence when you insert, remove, or reorder sequences.

Network and simulation

Network trace directions corrected
Network Trace Upstream and Network Trace Downstream now trace in the correct direction. Previously, the two tools were swapped.
Variable speed pump simulations allow isolated areas
Simulations with variable speed pumps (VSP) no longer stop when the network has isolated junctions with no demand. This matches the behavior of other simulations.