Internal category - Stingray Flow Node Reference

Internal category

Nodes

Outputs

Out

event

This event is triggered when the node finishes its evaluation.

Inputs

string

Name

The name of the sound bank to load.

boolean

Reference Count

If true, will increment a reference count for this bank, for us by the unload bank node.

unit

Unit

The unit to which a sound bank is loaded.

event

In

This event triggers the evaluation of this node.

Name must be the full resource name including project path, but without the file type extension. Banks are automatically loaded when a package containing the bank is loaded.

Available in External Flow Editor only.

Script node definition in file: core/wwise/wwise.script_flow_nodes