Use this procedure to create a stair interference area in a door/window assembly. When you add an interference condition between a stair and a door/window assembly, a box is cut out around the stair based on the specified headroom height and side clearance. You have the option of cutting the infills, frames, and mullions of the door/window assembly.
- Create a stair that intersects with a door/window assembly.
- Double-click the stair to open the Properties palette.
- Click the Design tab, expand Advanced, and expand Interference.
- Set the size of the interference condition:
If you want to… Then… specify the height above the treads for the interference condition enter a value for Headroom height. specify the left and right side clearances for the interference condition for straight and multi-landing stairs enter values for Left and Right Clearance. specify the inside and outside clearances for the interference condition for spiral and U-shaped stairs enter values for Inside and Outside Clearance. - Click in the drawing, not on the stair, to remove the selection.
- Select the door/window assembly to intersect, and click
.
- Select the stair.
- Specify whether to apply the interference condition to the infill, frames, or mullions of the door/window assembly.