Use this dialog box to create sample lines along an alignment for a specified range of stations.
General
- Alignment
-
Displays the name of the currently selected alignment associated with the range of stations.
Station Range
- From Alignment Start
-
Specifies whether the station range starts at the beginning of the alignment (that is, at the station located at the beginning of the alignment):
- True: Begins the station range at the start of the alignment.
- False: Specifies the beginning station in the range. Enter or pick a beginning station.
- Start Station
-
Specifies the beginning station in the range. Enter a station value directly or click
to pick from the drawing. Available if From Alignment Start is False.
- To Alignment End
-
Specifies whether the station range ends at the end of the alignment (that is, at the final station along the alignment):
- True: Ends the station range at the end of the alignment.
- False: Specifies the ending station in the range. Enter or pick an editing station.
- End Station
-
Specifies the end station in the range. Enter a station value directly or click
to pick from the drawing. Available if To Alignment End is False.
Left Swath Width
- Snap To An Alignment
-
Specifies that the sample line extends out to an alignment at each station (rather than being a hard-coded width).
- True: Creates the left swath by snapping to a specified offset alignment at each station. If you specify True, then select the alignment to use from the Alignment list.
- False: Does not snap to an offset alignment. If you specify False, then use the Width setting to specify the swath width.
- Alignment
-
Specifies the alignment to which the left swath is extended. Available if Snap To Alignment is True.
Note: Although all alignments in the current drawing are listed, do not select the parent alignment. The resulting length will be zero. - Width
-
Specifies the swath width to the left of the alignment, using the actual ground units. Enter a positive value in ground units. Available if Snap To Alignment is False.
Right Swath Width
- Snap To An Alignment
-
Specifies that the sample line extends out to an alignment at each station (rather than being a hard-coded width).
- True: Creates the right swath by snapping to a specified offset alignment at each station. If you specify True, then select the alignment to use from the Alignment list.
- False: Does not snap to an offset alignment. If you specify False, then use the Width setting to specify the swath width.
- Alignment
-
Specifies the alignment to which the right swath is extended. Available if Snap To Alignment is True.
Note: Although all alignments in the current drawing are listed, do not select the parent alignment. The resulting length will be zero. - Width
-
Specifies the swath width to the right of the alignment, using the actual ground units. Enter a positive value in ground units. Available if Snap To Alignment is False.
Sampling Increments
- Use Sampling Increments
-
Specifies whether sample lines are created at incremental stations along the alignment:
- True: Changes the default sample increments for either tangents, curves, or spirals. For example, you may want to decrease the values for curves and/or spirals.
- False: Sample lines are not created at stations along the alignment.
- Increment Relative To
- Specifies how the station range is incremented.
- Absolute Station: Increments the stations from station 0 of the alignment.
- Station Range Start: Increments the stations from the start station of the alignment (which may not be 0) or from the station specified under Station Range as the Start Station .
- Increment Along Tangents
-
Specifies the sample increment distance along tangents, using the actual ground units. Enter a positive value in ground units.
- Increment Along Curves
-
Specifies the sample increment distance along curves, using the actual ground units. Enter a positive value in ground units.
- Increment Along Spirals
-
Specifies the sample increment distance along spirals, using the actual ground units. Enter a positive value in ground units.
Additional Sample Controls
- At Range Start
-
Specifies whether a sample line is created at the beginning of the specified range.
- At Range End
-
Specifies whether a sample line is created at the end of the specified range.
- At Horizontal Geometry Points
-
Specifies whether additional sample lines are created at horizontal geometry points, such as, at the start of a spiral, or at a spiral-curve point.
- At Superelevation Critical Stations
-
Specifies whether additional sample lines are created at superelevation critical stations.