Known Issues in Autodesk Drainage Design and Analysis Tools 2026.1
This document lists known issues in Drainage Design and Analysis Tools 2026.1.
| General |
| A pipe cannot be connected during layout. To connect a pipe, create the pipe first and then use the grips to connect it to the stormwater control. |
| A pipe can be simultaneously connected to a pipe network structure, pond, and underground storage. |
| Pipe network structures cannot be connected to stormwater controls. |
| Only certain default values can be configured in the stormwater control command and feature settings. |
| The stretch and offset commands are not supported for stormwater controls. |
| Channel |
| There will be bowties at corners when longitudinal lines are turned on in the channel style. |
| When using the "Pick from Drawing" option to specify a station range, the temporary graphics have different styles depending on whether the baseline is an alignment/profile or a feature line. |
| Specifying a baseline station range does not support station formatting according to the channel feature settings. |
| Channel baseline station range does not support station equations. |
| Pond |
| The CreatePondFromSurface command may produce unexpected results for a surface containing holes. |
| Surface-based ponds do not maintain a link to the original surface they were created from. |
| The QuickEditPond and DeletePondContour commands may behave unexpectedly if pond contours are not visible. |
| The intersection object snap does not work with interior contours. |
| The deferred tangent object snap is currently not supported. |
| Rollover tooltips cannot be customized. |