Share

Issues Resolved

API
Fixed an issue to improve stability when calling itm.update() on sub-assemblies in the API.
Fixed an issue to improve support for long paths in the API.
Fixed an issue to improve resiliency when using the item load API.
Data Output
Fixed an issue so that overlay font setting persist in the nest print layout section.
Fixed an issue so the print order and number of copies for labels are persisted between sessions.
Database
Fixed an issue related to the connector straight adjust improvements so oversized notch depths develop the same as previous versions.
Fixed an issue to improve persistence of the default length setting when importing specifications into new profiles or other configurations.
Fixed an issue to persist message prompt options that are configured in CADmep.
Fixed an issue to reconnect competitive data when opening a job where the data had been removed.
Estimating
Fixed an issue to improve costing of complex node parts when using design line.
Framework
Fixed an issue so that version warnings display when using OPENJOB in CADmep or e-linking jobs in ESTmep that were saved in newer versions.
Fixed an issue to improve stability when switching to profiles that contain unexpected data.
Interoperability
Fixed an issue when accessing layers in ESTmep after deleting respective underlays.
Manufacturing
Fixed an issue to improve the timing of marking text when using sectioned machines.
Fixed an issue when setting up a custom NC when no .vlp files are available which could lead to stability issues.
Open GL
Fixed issue with invalid line types displaying on PDFs when selected.
Other
Fixed an issue so the welcome screen scales with the screen resolution.
Improved security for known vulnerabilities.
Pattern
Fixed an issue in ESTmep to suppress warning messages when connecting to step down connectors.
Fixed an issue on multiple patterns to show the C1 in the model viewer.
Fixed an issue on pattern 1205 to improve product stability by improving geometry checks.
Fixed an issue on pattern 8 to allow seams to mechanically join fitting extensions.
Fixed an issue on pattern 8 to remove duplicate connector labels in the development preview.
Fixed an issue on pattern 884 to improve stability with using integral dampers.
Fixed an issue on patterns (75, 751, 812, 891 & 2751) to improve stability when inputting 0 as the branch taper angle.
Fixed an issue on patterns 160 & 890 so the reducer is removed when using the 'no pipe' option.
Fixed an issue on rectangular patterns (2, 3 & 4) configured as double wall using a step down connector on end 2 to maintain consistent skin position.
Fixed an issue on shape change pattern 8 to ensure added hole position and shape match configured dimensions.
Fixed an issue on square to round patterns (8, 28, 29, 254, 324, 450 & 451) to extend inside wall to the part extents on the round end.
Fixed an issue to ensure material gauge displays correctly with the new material framework.
Fixed an issue to improve notch depths on patterns using step down connectors with a notch set to Notch Out.
Fixed an issue to improve the display of connectors when treating them as part of the main body.
Fixed an issue to improve the model geometry on pattern 834.
Fixed an issue to improve the visibility of the C3 connector label on pattern 916.
Fixed an issue with pattern length on rectangular mitred offset patterns (6, 30, 252, 460, 461) when using step down connector types.
Fixed an issue with the connector position on unlined parts using dynamic step down connectors.
Fixed an issue with the geometry validation when branches are configured as tangential on oval duct patterns (118, 135, 136, 140, 154, 159, 377, 378, 844, 846, 1115, 1116).
Fixed an issue with the rectangular bend fitting which could display unexpected extension warnings when the length matched the connector's straight property value.
Fixed an issue with the rectangular offset patterns (11 & 366) so that the skins are positioned correctly when configured as double wall.
Usability
Improved the connector preview when working with step down connectors.

Was this information helpful?