Synchronization codes that are associated with an operation must be output at the beginning of the operation. FeatureCAM allows up to five synchronization codes to be associated with a single operation. The following line mustappear in the Program Start, Tool Change, Segment Start and Program End program formats:
{M<SYNC1>}<EOB>
Note: This variable is specially programmed so that it is not output if the variable is blank.