If your tooling or feed/speed database becomes corrupt, you can recreate the databases using the INITDB program.
Warning: This procedure erases any changes you have made to existing tools or feed/speed tables and deletes any custom tooling or new feed/speed tables that you have created. Contact your
FeatureCAM support person before performing this task.
To remove your database and recreate it:
- Exit FeatureCAM if you are running it.
- Run Windows Explorer.
- Open the directory in which you installed FeatureCAM.
- Open the database directory.
- Click in the right-hand contents window.
- Click Select All from the Edit menu.
- Press the Delete key on the keyboard.
- In Windows, select Start > All Programs > FeatureCAM > INITDB.
- Select the units of tools you want to add. FeatureCAM does not alter any items that you changed or delete any items that you added.
- Click OK.