Fixed Issues
April 19, 2024
These release notes contain important information regarding issues addressed in the FDU 2025.
Fixed issues | Issue number |
---|---|
Improved stability when opening a DWG file by entering the file path in AutoCAD. | INVGEN-75537 |
Improved stability when closing Inventor after using Factory Design Utility. | INVGEN-75279 |
Improved stability when opening a layout reference created with an asset in AutoCAD. | INVGEN-75196 |
Resolved an issue where an asset library folder could not be moved from local storage to Vault if its name included special characters. | INVGEN-74928 |
Resolved an issue where Factory assets were saved in the default local storage while using the 'Open in NavisWorks' command. | INVGEN-73782 |
Resolved an issue where the mouse cursor lagged when copying, pasting, moving, or rotating in AutoCAD if the Factory Properties panel was open. | INVGEN-73376 |
Improved stability when dragging the Factory layout assembly in Inventor. | INVGEN-73294 |
Resolved an issue where constraints were duplicated when copying and pasting the Factory assets in an IAM file. | INVGEN-73018 |
Resolved an issue where a node state error appeared in the Model browser when defining a new connector. | INVGEN-72651 |
Resolved an issue where assets created from an AnyCAD model copied all converted files to the Factory Asset folder. | INVGEN-70811 |
Improved stability when opening the Factory layout in Inventor. | INVGEN-70750 |
Resolved an issue where the letter 'E' was converted to a scientific formula value when importing a property with the letter 'E'. | INVGEN-70717 |
Resolved an issue where a CancellationTokenSource error occurred when publishing an asset. | INVGEN-69940 |
Improved stability when opening a layout created with an old version of Factory Design Utility (e.g. 2022) in AutoCAD. | INVGEN-69335 |
Resolved an issue where the Factory asset wasn't updated when clicking 'Apply' while using the iLogic form: FactoryDesignProperties. | INVGEN-69291 |
Improved stability when opening a Factory layout file in AutoCAD. | INVGEN-69267 |
Improved stability when changing asset properties while logged into Vault in Inventor. | INVGEN-69109 |
Resolved an issue where the mouse cursor would hang when placing the pointer over an asset instance whose asset doesn't exist locally. | INVGEN-68962 |
Improved stability when opening a Factory layout file in Inventor. | INVGEN-68630 |
Resolved an issue where 3D models were not generated in Inventor when using AutoCAD commands (Copy, Rotate, Array, etc.) or Copy/Paste to duplicate FDU asset instances in AutoCAD. | INVGEN-68601 |
Resolved an issue where constraints were duplicated after using the 'Demote' and 'Infer Connections' commands. | INVGEN-67757 |
Improved stability when a modified asset file was closed while another file was opened before displaying the 'Publish Asset' dialog. | INVGEN-67702 |
Improved performance when using the 'Open in Inventor' command from AutoCAD when logged into Vault. | INVGEN-67622 |
Resolved an issue where annotations were not centered despite selecting the Center option in the Options dialog. | INVGEN-67560 |
Resolved an issue where objects would flicker when moving the mouse in Navisworks when certain Factory Design Utility commands were enabled. | INVGEN-67181 |
Resolved an issue where assets were not stored in the Obsolete Assets folder after editing. | INVGEN-65179 |
Improved stability when adding an asset with a connector to a Factory layout file in Inventor. | INVGEN-64673 |
Improved performance while opening and updating a Factory layout file from Vault when the Vault Factory asset folder contains multiple files. | INVGEN-61971 |
Improved stability when changing the Factory properties of an asset in Inventor. | INVGEN-61778 |
Resolved an issue where exposed connectors in the sub-layout within the Model States weren't visible in the top-level layout. | INVGEN-60804 |
Improved performance when opening a large Factory layout file. | INVGEN-60408 |
Improved stability when switching to simplified substitutes in a Factory layout file. | INVGEN-60344 |
Improved stability when opening a DWG file by entering the file path in AutoCAD. | INVGEN-60053 |
Improved stability when placing assets from the Vault Assets library if the 'No To All' option was selected. | INVGEN-58947 |
Improved stability when opening a DWG layout file in Vault. | INVGEN-58617 |
Resolved an issue where a LAYOUTDATA file, alongside an assembly, was not selected into Vault while closing an IAM file in Inventor. | INVGEN-53414 |