Share
 
 

Pipe Status

The Pipe Status tab allows you to designate specific pipes in which the actual field condition (open, closed, etc.) is unknown prior to calibration. During a steady state calibration, the pipe status will be allowed to vary for those pipes specified in order to correlate model data with field data. Following a steady state calibration, the resulting pipe status is shown in the Result Status field.

Main Menu

Mode - Choose a mode (Steady State, Fire Flow, or Extended Period) for Calibrator.

Run - Go to Run to Start and Stop the trial. You can also choose Options.... to view the Calibration Options dialog box: 

Help - Click to go to ContentsIndex, or About Calibrator to find more information on Calibrator.

Pipe ID

Enter the individual pipe ID that will be eligible for status change.

Result Status

Calculated status for the associated pipe.

Insert ID

Insert pipe ID to the active row by clicking on the individual pipe in the map view.

Update ID

Update pipe ID to the active row by clicking on the individual pipe in the map view.

Delete

Delete pipe ID of the active row.

Clear All

Delete all pipe IDs in the Pipe Status table.