Quick Start
The Quick Start guide offers an overview of the process for transforming raw data into a Moldflow UDB file using Autodesk Moldflow Data Fitting.
For Themoplastics:
Create a new material input data file (.aml)
- Click (File > New) to generate a blank data file
- Click (File > Save) to save data file to preferred location
Fill essential material data
- General Information (Compulsory)
- Filler (If applicable)
- Processing and Design (Compulsory)
- Specific Heat (Compulsory)
- Thermal Conductivity (Compulsory)
- Viscosity Input (Compulsory)
- PVT Input (Compulsory)
- Mechanical Input (Compulsory)
Fill optional material data if available
Check quality of material data
- Click (Check Input) to validate provided material data
- Error messages need to be fixed before proceeding to fit model
- Data with Warning messages can still be fit
Data fitting to relevant models
- Click (Compute Results) to fit the following material data to models:
- Viscosity Model
- PVT Model
- Ramberg-Osgood Stress-Strain Model (if data is provided)
- Click (Compute Results) to fit the following material data to models:
Check quality of fitted data
- Click (Check Results) to validate fitted Viscosity, PVT and Ramberg-Osgood Stress-Strain Model
- Error messages need to be fixed before proceeding to generate material data file (.udb)
- Data with Warning messages can still be exported
Generate material database file (.udb)
- Click (Generate UDB) to save material database file (21000.udb) to preferred location
For Thermosets:
Create a new material input data file (.aml)
- Click (File > New Thermoset) to generate a blank data file
- Click (File > Save) to save data file to preferred location
Fill essential material data
- General Information (Compulsory)
- Filler (If applicable)
- Processing and Design (Compulsory)
- Specific Heat (Compulsory)
- Thermal Conductivity (Compulsory)
- Raw Cure Kinetics (Model entry only)
- Raw Reactive Viscosity (Model entry only)
- Raw PVT (Uncured) (Compulsory)
- Raw PVT (Cured) (Compulsory)
Fill optional Mechanical Input data if available
Check quality of material data
- Click (Check Input) to validate provided material data
- Error messages need to be fixed before proceeding to fit model
- Data with Warning messages can still be fit
Data fitting to relevant models
- Click (Compute Results) to fit the following material data to models:
- PVT Model (Uncured)
- PVT Model (Cured)
- Cure Kinetics Model, enter model coefficients
- Reactive Viscosity Model, enter model coefficients
- Click (Compute Results) to fit the following material data to models:
Check quality of fitted data
- Click (Check Results) to validate fitted Uncured and Cured PVT Models
- Error messages need to be fixed before proceeding to generate material data file (.udb)
- Data with Warning messages can still be exported
Generate material database file (.udb)
- Click (Generate UDB) to save material database file (20030.udb) to preferred location