Hybrid element activation *DDM! is used without a laser path using *LSRP or *LASR or a PRM file set by *PBPF. Check and correct the input files.
This error is shown when a user includes the hybrid element activation card *DDM! without a laser file or PRM file.
Hybrid element activation *DDM! error: top substrate coordinate is lower than substrate based. Ensure the values are correct and in the correct order.
This error occurs when the base of the STL file floats above the top of the substrate as specified by *DDM!.
DDM* elements activated when heat source is active at time= ##. Check *DDM* values.
Elements cannot be activated when the heat source is active. Adjust the timing used by the *LSRF or *DDM! cards.
The homogenized geometry is empty. Try using a larger alpha radius (maximum cell radius) or check the input geometry.
This error occurs when automatic homogenization has been enabled but the alpha radius has been set so small that no geometry is created. Increase the alpha radius in the *STLH card to correct this problem.