Heat Treatment Model Warnings

*STRF card requires the time values to be positive.
*STRF card will be ignored
*STRF card requires the time values to be
entered in ascending order
*STRF card will be ignored
*STRF card requires the heat treatment history
to be specified
*STRF card will be ignored

These warnings occur when the heat treatment modeling history is improperly specified. If this occurs, the simulation will run but will not perform the heat treatment modeling.

Stress relaxation *STRF can only be used when
part-level plasticity *PPLA is ON
*STRF card will be ignored

This warning occurs when a user attempts to model heat treatment without using part-scale plasticity. If this occurs the simulation will run but will not perform the heat treatment modeling.