*CONV
r11, r12
r21, r22
...
r11: r*8: Convection at temperature r12
r21: r*8: Convection at temperature r22
...
This allows for the definition of a temperature dependent convection in W/mm2 oC for temperatures specified in oC. Convection is automatically applied to the free surfaces of *AUTM auto-generated meshes. These values are also used at the interface of quiet and active elements (unless *DDMP is turned on).