- Click Tools tab > Simulator panel > Dual Column > Machine Position Calibration.
The Calibration Mode page of the Dual Column Calibration Wizard is displayed.
- Select Quick and click Next. The Probing Method page is displayed.
- Select CNC-assisted to measure the calibration items in CNC mode and click Next. The Basic Setup page is displayed.
- In the Anchored to list, select the column you want to use to determine the machine datum.
- If you want to view or change the transformation matrix created by the original calibration:
- Click Transform. The Transformation Matrix dialog is displayed.
- Edit the transformation and click OK to close the dialog and save your changes.
- Click Next. The Definition of Calibration Objects page is displayed.
- Click
to create the items that you want to use to calibrate the columns. Specify one or more calibration items that can be probed from both columns.
- Click Next. The Default Calibration Sphere Geometry page is displayed.
- Enter the details of the largest calibration sphere you want to use:
- In the Diameter box, enter the diameter of the sphere.
- In the Stem diameter box, enter the diameter of the sphere's stem.
- In the Direction from the base to the sphere list, specify the vector from the base to the sphere.
- Click Next. The wizard displays a message telling you to switch to column 1.
- Click Next. The Default CNC Settings for Probing Spheres page is displayed.
- Enter the default probing details for the column:
- In the Initial contact list, specify the direction from which you will manually probe the sphere.
- In the Number of points box, enter the number of points to be probed automatically. You must specify at least four points.
- Click Next. The Default Probe Direction for CNC Probing page is displayed.
- Specify the default vector from the probe head hinge point to the stylus tip.
- Click Next. The Measuring page is displayed.
- For each entry in the list of spheres:
- If you want to override the measurement settings for this sphere, click the Sphere Geometry, Sphere Probing, or Probe Direction buttons.
- Manually probe a point on the sphere. The Run button is enabled.
- Click Run to probe the sphere. When probing is complete, the coordinates of the sphere's centre are displayed in the Measuring status list.
- When you have probed all the spheres in the list, click Next. The wizard displays a message telling you to switch to column 2.
- Repeat steps 11 to 16 for column 2, making sure to probe the spheres in the same order as that used for column 1.
- When you have probed all the spheres in the list, click Next. The Result page is displayed.
- The
Deviation box displays the positional difference when the calibration measurements are applied to the original transformation matrix. Click:
- Show Calculated Matrix to display the adjusted transformation matrix.
- Back to reprobe the calibration items if the deviation is outside acceptable limits.
- Finish to accept the results and close the wizard.