AnalyticalTransformerData.SecondaryDistributionSystem Property

The secondary distribution system of the analytical transformer.


Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.3.0.0 (25.3.0.0)

Syntax

C#

public ElementId SecondaryDistributionSystem { get; set; }

Property Value

ElementId

Exceptions

ExceptionCondition
ArgumentException When setting this property: The id is neither a distribution system id nor InvalidElementId. -or- When setting this property: The secondary distribution system id can't be set to the analytical transformer.
ArgumentNullException When setting this property: A non-optional argument was null

Remarks

In the case of a transformer, it's crucial that the number of phases in the secondary distribution system matches that of the primary distribution system. If the number of phases in the secondary system is set to be different from that of the primary distribution system, it will result in a 'SecondaryNumOfPhasesNotEqualWithPrimary' error. If you anticipate this discrepancy, you can avoid the error by first setting the secondary distribution system to InvalidElementId, and then setting the primary distribution system.