Share

AS 5100 (2017) Errors and omissions update (Unofficial)

Description

The option is accessed through File | Options | Preferences in the Main Menu.

This Preferences option activates a number of fixes to address errors and omissions in Australian Standards 2017 Amendment 1. Note that these have not been made official design code submissions at the time of the software release.

This list details the changes that this option will enable:

  • 8.2.1.2 Consideration of torsion

    σcp = stress at the centroid of the cross section, or at the junction of the web and flange when the centroid lies inside the flange due to prestress and axial force.

    pc changed to uc in equation 8.2.1.2(2) and 8.2.1.2(3)

  • 8.2.1.6(a) Requirements for transverse shear reinforcement

    Parentheses removed and shear depth factor f introduced, where f=0.5 for dv ≥ 0.6m, and f=1.0 for dv ≤ 0.3m .

    V* > fϕVuc + Pv

  • 8.2.3.1 Design shear strength of a beam

    Applied shear V* used in place of equivalent factored shear force V*eq:

    ϕVuV*

  • 8.2.3.3 Shear strength limited by web crushing

    Pv removed from the equation 8.2.3.3(1) and 8.2.3.3(2).

  • 8.2.4.4 Determination of εx for combined shear and torsion

    Equation 8.2.4.4(3) revised to:

    M* ≥ ( V* - Pv ) dv


Top of Page

Was this information helpful?