In this tutorial, you:
Created a project
Imported an existing study
Duplicated a single part to create a 4-cavity mold
Created a runner system
Set up and ran the analysis
Reviewed results
Be Adventurous
The results are less than ideal. Try to reduce the cooling time for the runners by reducing the sprue and runner diameters.
Save the study with a different name.
Select an element in the sprue
Right click and select Properties
Select Edit properties of the entire taper section and click OK.
Set the diameter of the sprue to a value of your choice.
Change the diameter of the runners as well.
Run another analysis and compare results.