Chapter 14: Measuring Part Temperatures

Previous: Chapter 13 | Next: Exercise 7

Use Results Parts to assess results on selected parts. Results Parts can also be designated as Summary Parts, and used in the Decision Center to assess Critical values.

An example of using a Result Part is an electronic power inverter. The temperature on several components cannot exceed a value of 60°C. After the Scenario is run to convergence, obtain the temperature on each component using the Part dialog.

To compare the resultant temperature on a component from several Scenarios in the Design Study, make them Summary Points, and compare their values in the Decision Center.

Extract results from:

To view results

  1. Click Results (tab) > Results Tasks (panel) > Parts to open the Parts dialog.
  2. Select parts of interest from the model.
  3. Click Calculate either on the Parts dialog or from the Parts context menu.
Note: To change units, make the part a Summary Part, and modify the units in the Critical Values table.
Note: Part-based results are computed on a nodal basis.

To designate a part as a Summary part

Note: once a Part is designated as a Summary Part, it cannot be deleted with the Remove button. To delete a Summary Part, open the Decision Center, right click on the Part, and click Remove.

Previous: Chapter 13 | Next: Exercise 7