Panel Missing Level/Sequence Assignments Data Fields to Report Dialog Box
Specifies which fields to include in the report, the field order, and the field labels.
Note: The Missing Level/Sequence Assignments report will not be available in future releases.
Find
Command entry: AEPANELREPORT
Select Missing Level/Sequence Assignments from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
Available Fields
Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
Fields to Report
Specifies the fields to display in the report, and the field order.
Remove
Removes the selected field from the Fields to Report list.
Remove All
Removes all the fields from the Fields to Report list.
Move Up
Moves the selected field up one spot in the Fields to Report list.
Move Down
Moves the selected field down one spot in the Fields to Report list.
Change Field Name/Justification
Specifies the field label and justification for the selected field.
Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
TAGNAME
Component tag value
INST
Installation value
LOC
Location value
MOUNT
Mount value
GROUP
Group value
HDL
Handle number of the component block
CATEGORY
Type of component: J = plug-jack connector, P = PLC I/O, C = cable marker
DESC1-3
Description 1-3 values
SH
Sheet value (%S) for the drawing where the component is located
SHDWGNAM