To resolve the issues, right-click the message, and start one of the commands to further explore the issue.

Warning

Description

No Industry Model With The Name <name> Defined For Used Field Code <field code> Exists In The Project.

Step 3, Find Reference Points.

The measurement contains a base point with a field code that points to an industry model that is not in the current project . Under Project Manage, check the field code list.

If the industry model name is displayed in {}, use Fill Industry Models to replace the placeholder. See Fill Industry Model.

No Field Code Definition For Used Code <field code>.

Step 3, Find Reference Points.

The measurement contains a base point with a field code that is not specified in the field code list. Under Find Reference Points, click the Manage Field Code List link, and check the field code list.

No Approximate Coordinate Available For The Point.

Step 4, Calculate Approximation.

The approximate coordinate could not be determined. Check the measurements and coordinates. For example, add missing measurements.

Measurement In Session With The Maximum Difference To Expected Orientation.

Step 7, Calculate Adjustment.

Indicates a possible error on the horizontal angle measurement. Check the measurements. Check for Critical Identical Points.