Create a New Design Scenario

We create a new design scenario for the transient stress (direct integration) analysis This action preserves the setup and results of the natural frequency – modal analysis along with any other analyses you might have set up and solved in other design scenarios.

Tip: Modal results are NOT required as a prerequisite to running a transient stress (direct integration) analysis.  However, they are required for a transient stress (modal superposition) analysis.  The direct integration method is recommended when shock-type loads are applied to the structure.  
  1. If you are continuing from a prior Truss Tower analysis and are still in the Results environment, click the FEA Editor tab at the top of the browser (tree view).
  2. Right-click the Analysis Type heading in the browser and select Set Current Analysis Type Linear Transient Stress (Direct Integration).
  3. Click Yes in the dialog box to create a new design scenario, rather than changing the analysis type for the current one.

Next