In this tutorial, you have the option to continue with the FEM Cooling Analysis Quick Start Tutorial model. You need to change the Analysis sequence to
Cool(FEM)+Fill+Pack+Warp. Running this analysis can take in excess of 1 hours.
Alternatively you can download a completed analysis and review the warpage results.
To use your model:
- Change the Analysis Sequence to
Cool(FEM)+Fill+Pack+Warp
- Ensure:
- Material -
Generic ABS:Generic Shrinkage Characterised Material
- Coolant inlet temperature -
40C
- Melt Temperature -
230C
- Mold-open time -
5 sec
- Injection+Packing+Cooling time -
15 sec
- Mold temperature options -
Averaged within cycle
You need to select
Isolate cause of warpage to understand the analysis further.
- Click
().
- Click
Advanced Options and
Edit from the
Solver parameters panel.
- Select the
Warp Analysis tab and select
Isolate cause of warpage from the
Warpage analysis type panel
- Click
() to run the analysis locally.