Advanced properties are collapsed by default. To view advanced properties, click (Down arrow).
Properties | Action | Selections |
---|---|---|
Connection details |
Click to open the Connection Details worksheet. |
|
Lining thickness |
Enter the lining thickness for the duct segment. |
0 (default) |
Insulation thickness |
Enter the insulation thickness for the duct segment. |
0 (default) |
***Assinged engineering ID | Specifies the engineering ID of duct fitting used for duct fabrication. |
Routing | Action | Selections |
---|---|---|
*Slope format |
Specifies the current slope format. The slope format affects the slope property (for example, as a fraction, decimal, or percentage). Note: Click (Preferences) to edit the slope format in the Duct Layout Preferences worksheet.
|
Available slope formats:
|
*Slope |
Specifies a slope value (rise/run in previous releases) that reflects the slope format. Note: If you change the slope value while you are adding more duct parts to a run, a fitting will be added to adjust the slope.
|
0 (default) |
*Branch fitting |
Select the fitting combination you want to use when adding a branch. |
|
*Terminal-Duct connection |
Specify the way to connect terminals to ducts. |
|
**Fitting settings |
Click to open the Fitting Settings dialog box. | |
*Preferences |
Click to configure duct layout preferences. |
Labels | Action | Selections |
---|---|---|
Style |
Specify the label style for the duct run. |
|
Flow arrows | Action | Selections |
---|---|---|
Style |
Select the flow arrow style for the duct run. |
|
**Graphics | Action | Selections |
---|---|---|
**Graphics | Specifies the pattern for flexible duct. Note: For more information, see Drawing Flexible Duct.
|
***Vanes | Action | Selections |
---|---|---|
**Graphics | Select whether adding vanes to the duct fitting or not. Note: For more information, see Drawing Flexible Duct.
Graphics User Interface |
|