How to specify the gap between the first and second welding processes, and the gap between the welding process and the contour symbol.
- At the Command prompt, enter AMOPTIONS.
- In the Options dialog box, click the AM:Standards tab.
- In the Standard Elements list, double-click Welding. The Welding Settings dialog box appears.
- In the Symbol Size section, in the Process gap box, specify the size of the gap.
- Click OK until all dialog boxes close.