The design verification considers the SLS and ULS combinations created with the model.
- Select the Steel Design layout, or Timber Design layout.
Note: Alternatively, Click

(Steel/Aluminum Members Design), or

(Timber Members Design) on the toolbar.
- In the Calculations dialog, select the type of verification that you want to perform, and then enter the list of elements that you want to verify.
Note: Alternatively, click List to select the list of elements that you want to verify.
- If necessary, click Options to review the optimization options.
- Specify which limit states you want to include in the verification:
Note: For serviceability limit states (SLS), specify the list of load cases that you want to consider during the analysis.
- Ensure that the Save calculation results option is selected.
Note: Saving the calculation results is useful if you want to perform several verifications on the same model, and avoid time-consuming recalculations. You can deselect this option if you do not want to save your calculation results.
- Click Configuration to set up the calculation parameters.
- In the Configuration dialog, specify the number of calculations points and the calculation parameters, and then click OK.
- In the Calculations dialog, click Calculations.