If a DAM analysis was run on the model, the steel design verification uses these results automatically.
If a DAM analysis is active, the analysis verifies the ULS and SLS as follows:
- The ULS verification is performed using the ULS combinations created with the DAM model.
- The SLS verification is performed using the SLS combinations created with the Main model.