You can add ancillaries during pressure network layout or editing. Unlike pressure pipes and fittings, ancillaries are categorised by type (such as valves) rather than by material.
In plan view, ancillaries can be added to the ends of a pipe or inserted anywhere along a pipe. Layout cues are displayed to indicate where the ancillaries can be inserted.
Ancillary Adjustments | Adjustment Example |
---|---|
To continue a pipe run through an ancillary, select the pipe run and click (Continue Layout). If the pipe size is available from the drawing part list, the pipe will resize to match the ancillary port. |
|
Select the ancillary and click (Flip) to flip its orientation. |
|