To perform an inspection on a CNC machine

Use the Run Program tab to run the inspection sequence on a CNC machine.

To perform an inspection:

  1. Resolve any probe path verification faults.
  2. If you are connecting to the measuring device using the I++ protocol, ensure that all the probe assemblies and positions you have specified in your document are specified and calibrated in the I++ Server.
  3. If the document is not connected to the measuring device, click Home tab > Document panel > Attach.
  4. Check the probes specified in your document are available and calibrated on the measuring device.
  5. Fix any probe errors shown in the Info.
  6. Run the inspection sequence on the measuring device.