Legacy smoothing tolerance

Legacy smoothing uses Smoothing Tolerance for line-to-arc fitting. It limits how far fitted arcs may deviate from the linear segments they replace.

The Smoothing Tolerance parameter is located in Compare and Edit. It helps you review and compare tolerance values across operations. See Compare and Edit reference.

Note: For example, Smoothing Tolerance of 0.01 mm means fitted arcs can vary from the linear path by up to 0.01 mm plus Tolerance set on the Passes tab.

Backward compatibility

Historically, Smoothing Tolerance appeared on the Passes tab under Smoothing, as in the image below.

smoothing dialog section

Legacy Smoothing and tolerance on the Passes tab

Existing operations stay backward compatible. Fusion does not automatically change stored Tolerance or Smoothing Tolerance when you open, copy, or regenerate an operation. The operation still uses those stored values, but Smoothing Tolerance is viewed and edited in Compare and Edit.

When stored Smoothing Tolerance is non-zero, a message on the Passes tab can indicate that legacy smoothing tolerance still affects the toolpath while Smoothing is on. To align the operation with the current workflow, set Smoothing Tolerance to 0 in Compare and Edit and adjust cut Tolerance as needed.

What to expect

Situation What to expect
Existing operation with non-zero smoothing tolerance Stored values kept. Edit Smoothing Tolerance in Compare and Edit. Legacy message on the Passes tab when Smoothing is on.
Copy or derive an operation Copied operations keep the source Smoothing Tolerance and legacy behavior.
Set Smoothing Tolerance to 0 in Compare and Edit Operation follows the current smoothing workflow (no legacy Passes tab message when Smoothing is on).
Template or library operation Stored Smoothing Tolerance and legacy rules apply the same as for any other operation.