In this activity, you include a fan to see how it can further reduce the component temperatures to below their maximum temperature thresholds of 130 C. The fan has already been modeled, but has been removed.
You create two studies, one to see the effect of pulling air out of the enclosure, and one to see the effect of pushing air into the enclosure.
To study the effect of blowing air through the enclosure you
Electronics enclosure with no fan (left) and with one fan (right).
Create a clone of the Two Heatsinks Simulation model and its associated study setup, and name it Fans, so you can modify it without overwriting existing results.
Reinstate the fan.
Rename the study to 50 W Fan Push.
In the Browser, confirm Simulation model Fan is active and double-click Study 1 - Electronics Cooling to activate edit mode.
Change the name to Fan Push, then press Enter on your keyboard.
Apply component idealization to the fan, to reduce the analysis time while maintaining solution accuracy, and set the flow rate to 41 CFM to push air into the enclosure.
On the Setup toolbar, in the Cooling panel, select Fan to open the Fan dialog.
In the canvas, select the fan and confirm it is highlighted in blue.
In the Fan dialog, confirm that 1 Body is selected, then set the Flow Rate to 41 CFM.
Click OK to accept the changes and close the dialog.
Clone the 50 W Fan Push study, name the new study 50 W Fan Pull, and reverse the direction of flow.
In the Browser, right-click study Fan Push and select Clone Study from the context menu.
In the Browser, double-click the new study, Fan Push (2), to activate edit mode.
Rename the study Fan Pull and press Enter on your keyboard.
In the Browser, click Edit associated with the fan to open the Edit Fan dialog.
In the Fan dialog, click Flip Direction to reverse the direction of flow.
Click OK to accept the changes and close the dialog.
Check that the studies are setup properly, then run the analyses.
On the Setup toolbar, check (Solve panel > Pre-check), and confirm it is green with a white check mark.
Switch to the other study and confirm that Pre-check is green.
On the Setup toolbar, click (Solve panel > Solve), to open the Solve dialog.
In the Solve dialog, select both studies, then click Solve 2 Studies to run them analysis and close the dialog.
When the analyses are complete, click Close to close the Job Status dialog.
In this activity, you