Inlets allow flow from Inflows or from an incoming Connections to be captured and routed into Junctions, Manholes, Stormwater Controls (SWC) or bypassed to another location.,
Inlets are created as part of a Junctions, Manhole or Stormwater Control to stipulate how much of the approaching flow will enter the structure.
Each system can have one or more inlets with each inlet able to support multiple incoming inflows and connections.
Inlet Types
It is possible to specify how the incoming flow will enter the system as this will affect the time it takes the water to pass through the Stormwater Controls - SWC. The Inlet types are:
- Point Inflow - The flows passing through are seen as entering at the top end of the Stormwater Controls - SWC.
- Lateral Inflow- The flows passing through are seen as entering along the length of the Stormwater Controls - SWC.
Inlet Destination
It is possible to specify which component of a complex SWC an inlet connects to. This option is only available for Bioretention or Swale (with Trench on) SWC types.
Bioretention SWC - When a soil layer is enabled, there are three inlet destination options:
- Surface Layer - Flows enter at the top of the bioretention system into the ponding area.
- Soil Layer - Flows enter directly into the middle soil/filter layer, bypassing the ponding area above.
- Storage Layer - Flows enter at the bottom of the bioretention system into the storage/gravel layer.
Swale SWC (with Trench enabled) - There are two inlet destination options:
- Ponding Area - Flows enter at the top of the system into the swale channel.
- Subsurface Area - Flows enter at the bottom of the system into the trench beneath the swale.
Incoming Items
This is the list of incoming Inflows and Connections that are entering the given inlet. Use the check boxes to select which items connect to each inlet of the SWC or Junction.
Bypass Destination
This is the destination connection that any flow bypassing the inlet will be routed. This needs to be drawn as a Bypass Connection on the Plan.
Capacity Type
There are several types of Inlet capacity that can be specified:
- No Restriction - The incoming flow enters the system unrestricted.
- Low/High Flow - Specify a low and high filters that are applied to the flow to determine how much flow enters the system.
- Rated by Flow - Specify Approach Flow vs Captured Flow as a table.
- HEC-22 - Specify an inlet compliant with HEC-22.