The following lists detail the various maintenance fixes made in InfoWater Pro version 2025.2.
For a list of the latest features and improvements in the current release, refer to What's New.
Improved reliability of Design Fireflow Accelerated Solver
In some models, the accelerated fire flow solver did not achieve convergence at all nodes with valid results from the traditional solver. The algorithm has been improved and, based on the sample models tested, is observed to converge in all cases that the traditional solver does.
Increased tolerance on displaying low flows
InfoWater Pro previously had a flow tolerance threshold of around 0.022 gpm, so small demands on Junctions could appear as showing zero downstream flow. This threshold has been reduced to 0.0022 gpm, or the equivalent in other units.
Support for UDF flow arrows on top of standard run flow arrows
An issue prevented flow arrows on UDF layers and base pipe flow direction from standard runs from working at the same time. This is now resolved.
SCADA runs with an SDA file now support steady state
SCADA runs previously ignored the SDA file for steady state runs. This is now fixed so that the SDA file overrides specified hydraulic states during the run.
Info360 Asset upload failing in 2025.1