Share

WSDemandAllocation

Used to allocate customer points to pipes in the network. The options and behavior of this class broadly match the static demand allocation tool in the user interface.

To use the methods of this class, you need to create an instance using the #new method and call the remaining methods.

network = WSApplication.current_network

allocator = WSDemandAllocation.new()
allocator.network = network
allocator.options = {'max_dist_to_pipe_native' => 200.00, 'max_pipe_diameter_native' => 200.00}
allocator.allocate

Methods:

allocate

#allocate ⇒ void

EXCHANGE, UI

Performs the allocation. Will raise an exception if the allocation fails.

demand_diagram= (Set)

#demand_diagram=(ddg) ⇒ void

EXCHANGE, UI

Optionally sets the demand diagram.

Parameters

Name Type(s) Description
ddg WSModelObject The demand diagram to use.

network= (Set)

#network=(network) ⇒ void

EXCHANGE, UI

Sets the network to allocate demand for.

Parameters

Name Type(s) Description
network WSOpenNetwork The network to use, must be of type geometry.

new

#new ⇒ WSDemandAllocation

EXCHANGE, UI

Creates a new instance of this class.

options

#options ⇒ Hash

EXCHANGE, UI

Gets the current option, including all default values.

options= (Set)

#options=(hash) ⇒ void

EXCHANGE, UI

Sets the options to use for the allocation. The options hash can contain the following keys:

Key Type Default
allocate_demand_unallocated Boolean true
allocated_flag String
exclude_allocations_flag String
exclude_allocations_with_flags Boolean false
ignore_reservoirs Boolean true
max_dist_along_pipe_native Float 0.0
max_dist_to_pipe_native Float 0.0
max_distance_steps Integer 1
max_pipe_diameter_native Float 0.0
max_properties_per_node Integer 0
node_within_cp_polygon Boolean false
only_pipes_within_polygon Boolean
only_to_nearest_node Boolean true
only_to_selected_nodes Boolean false
reallocate_demand_average Boolean false
reallocate_demand_direct Boolean false
reallocate_demand_property Boolean false
remove_demand_average Boolean false
remove_demand_direct Boolean false
remove_demand_property Boolean false
restrict_allocations_to_polygon Boolean
use_connection_points Boolean false
use_nearest_pipe Boolean true
use_smallest_pipe Boolean false