When you digitize water network features, a feature rule sets the supply zone for a line feature if it is located within a zone. If the feature is located in overlapping zones, you are prompted to select a zone. If you choose Yes, you can select a zone. If you choose No, the pressure zone value is cleared.
Note:
If you digitize a supply zone while the water network features already exist, the pipes are not updated and do not belong to the supply zone.
You can use a feature function to update the relations. See also Connect Features to a Zone.
- Start Infrastructure Administrator and open the Water workspace.
- Click Industry Model menu
Data Model.
- Expand the Utility topic and select the Line feature class (WA_LINE).
- Right-click and click Edit Feature Rules.
The Feature Rules Properties dialog box is displayed.
- In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
- In the Applied Rule Bases list, enable or disable the SetSupplyZone_BIU and the SetSupplyZone_AIU rules.
- Click Save & Close.
- Expand the Pipe topic and select the Pipe feature class.
- Right-click and click Edit Feature Rules.
- In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
- In the Applied Rule Bases list, enable or disable the SetSupplyZone_BI rule.
- Click Save & Close.