The CreateStartEndNode feature rule controls the automatic creation of network points.
If you create a pipe with a start or end that is not connected to a network point, a fitting is created. Sometimes the water network does not continue beyond a certain point. If you need to create non-ending pipes, you can disable this feature rule. Also, you can configure the feature rule, so that a network point of any type is created.
If you create a control cable with a start or end that is not connected to a network point, a cable point is created.
- Start Infrastructure Administrator and open the Water project .
- Click Industry Model menu
Data Model.
- Expand the Utility topic and select the Line feature class (WA_LINE).
- Right-click and click Edit Feature Rules.
The Feature Rules Properties dialog box is displayed.
- In the Feature Rules Properties dialog box, click the Client Side (.NET) tab.
- In the Applied Rule Bases list, enable or disable the CreatetStartEndNode rule and click Edit.
The Edit Rule Base dialog box is displayed.
- In the Edit Rule Base dialog box, do the following:
- Select or clear the Active option.
Optionally, you can also enable or disable the feature rule in the Feature Rules Properties dialog box.
- In the Parameters field, specify which point feature class to create. For example, WA_FITTING.
- Click OK.
- Select or clear the Active option.
- Click Save & Close.