- Click Design
Steel Members Design - Options
Verification The Manual verification dialog displays.
- Enter the member number in the Verification of member no. box.
- Enter the values of the appropriate internal forces in the Internal forces in the analyzed section box. The corresponding units are displayed in the right, upper corner of the dialog.
- Enter the values of the additional internal forces required for code calculations in the Internal forces in characteristic sections box.
- In the Load type field, select a load type to be applied to the verified member in Y-axis or Z-axis direction. Once the icon is selected, a dialog for a load type definition is displayed.
- Click the Options button to select the Calculation Options.
- Click the Calculations button. The member is verified and the result is displayed.