Use the Boundary Condition Settings tab of the Structural Settings dialog to specify family symbols and adjust the spacing four each boundary condition representation.
- Click Manage tab
Settings panel
(Structural Settings).
- Select the Boundary Conditions Settings tab.
- Under Family Symbol, select a symbol for the Fixed, Pinned, Roller, and User Defined boundary condition states.
Four symbol families are pre-loaded in structural templates. These families can be duplicated and edited to meet your display standards or needs. If the families are not loaded, you must first Load a Family in order to specify it in this dropdown list.
- Specify the desired distance in the Area and Line Symbol Spacing field to complete the Boundary Conditions settings.